JPRO DEF Dosing Valve Test for MACK and Volvo EPA 13 to GHG17 Engines

Follow these steps to perform a Diesel Exhaust Fluid (DEF) Metering Valve Test on Mack and Volvo engines EPA 13 – GHG17 using a JPRO diagnostic tool: This test is important to ensure the dispensing system is operating properly and can also be used to exit induction mode after replacing a dispense valve and clear any associated Diagnostic Trouble Codes (DTCs).

Steps to Perform the DEF Dosing Valve Test

1. Select the DEF Dosing Valve Test

– Launch the JPRO diagnostic tool.

– Navigate to the DEF Dosing Valve Test and press Enter or click the Start button.

2. Configure Monitored Data

– The tool will display the Configure Monitored Data screen for the DEF Dosing Valve Test.

– Select parameters from the Available list and click the Add button to move them to the Selected list.

– To remove parameters from the Selected list, highlight the parameter and click the Remove button.

– Once done selecting parameters, click the OK button to proceed, or Cancel to return to the test selection dialog.

3. Review Test Information

– The DEF Dosing Valve Test dialog will provide important information about steps to take before running the test.

– Click the Next button to view detailed test instructions.

4. Prepare for the Test

– Follow instructions for removing the DEF Dosing Valve.

– Click the Next button to continue.

5. Preconditions and Test Selection

– Ensure all preconditions are met for the test.

– Select the specific DEF Dosing Valve test to perform.

– Click the Start button to begin the test. This process may take a few minutes.

6. Observe Spray Patterns and Quantity

– The dialog will display examples of correct and problematic spray patterns.

– Observe the valve as it dispenses DEF into the collection container.

– The amount of DEF measured will determine the next steps in diagnostics or repairs.

7. Review Test Results

– Upon test completion, the results will be displayed, including steps to take based on the quantity of DEF dispensed.

– If needed, you can perform the test again by clicking the Test Selection button.

8. Post-Test Procedures

– Follow the instructions to ensure sufficient post-ventilation of the dosing system.

– Click the Exit button to return to the bi-directional test selection dialog.

Additional Resources

– For more detailed guidance and troubleshooting, refer to the JPRO Diagnostics Guide.

By following these steps, you can effectively perform the DEF Dosing Valve Test on Mack and Volvo EPA 13 to GHG17 engines using the JPRO diagnostic tool, ensuring proper operation of the dosing system and addressing any issues that may arise.

Be the first to comment

Leave a Reply

Your email address will not be published.


*