Doosan G2 Stage V Machine P00BE Sensitivity Drift Error Solution

This guide provides step-by-step instructions on resolving the P00BE Sensitivity Drift Error (Low) for the air mass flow sensor in Doosan G2 Stage V machines.

Preparations:

Doosan Data Monitoring System DMS-5 DMS-3 Free Download
Doosan Diagnostic Tool DDT & G2 Scan Software
Doosan uVIM Diagnostic Tool

Overview

Error Code: E SPN-FMI: E00013221

Possible Causes:

  1. Air Path Issue – Leakage between the air cleaner and compressor inlet.
  2. Installation Issue – Incorrect installation or reverse positioning of the air mass flow sensor.
  3. Electrical Issue – Malfunctioning components, including:
    • Faulty intake manifold pressure sensor
    • Faulty intake manifold temperature sensor
    • Faulty air mass flow sensor

Effects of the Error:

  • CE Lamp: Blinking or stays ON
  • Torque Reduction: Severe (Level 2)
  • Inducement Group 1 (EGR Block):
    • If EGR is present, DPF regeneration is inhibited (both active and forced).

Component Location

The air mass flow sensor’s location varies based on the machine application.

Diagnostic Conditions

  • Engine must be running.

Fault Code Trigger Conditions

The fault code is set when the measured air mass flow sensor value deviates beyond the acceptable threshold compared to the calculated airflow into the cylinder.

Fault Code Clearing Conditions

The fault code is cleared when the air mass flow sensor’s measured value returns within the acceptable range compared to the calculated airflow into the cylinder.

Checklist for Troubleshooting

More topics for Doosan,please refer to:Doosan Trouble Repair