This guide explains how to diagnose and repair the Deutz EMR3 engine error 71 / 2791 / EGRCD_SigNpl, which relates to the EGR actuator circuit.
Related Contents:
Deutz Serdia 4.0 Serdia 2010 v14.1.9.1 Diagnostic Software Free Download
Deutz Diagnose Kit for Deutz Engine Communicator Deutz Decom Diagnostic Heavy Duty Scanner
Error Description
System: Deutz EMR3
Component: External EGR Actuator
Fault Summary:
The ECU detects no load or an excessive temperature condition in the internal ECU power supply circuit for connected components. This indicates a potential issue with the EGR actuator, wiring, or ECU driver circuit.
Error Details
- Deutz Error Code: 71
- Blink Code (short–long–short): 4 – 1 – 5
- SPN: 2791
Possible FMI Values:
- 5: Current too low or broken wire
- 2: Data stream defective
Error Detection
- Error Lamp: Permanently illuminated
- Error Memory: Fault stored in ECU memory
Possible Causes
- Open circuit or short in EGR actuator wiring
- Overheating or internal fault in ECU
- Defective EGR actuator or position sensor
- Damaged or corroded connectors
- Power or ground supply issue
Repair Actions
- Visual Inspection
- Inspect the wiring harness between the EGR actuator and ECU.
- Look for broken wires, melted insulation, or corroded terminals.
- Check Connections
- Ensure all connectors are properly seated and free of dirt, moisture, or corrosion.
- Clean and reconnect if necessary.
- Test the EGR Actuator
- Use a multimeter to measure actuator resistance and verify against specifications.
- Replace the actuator if it fails the test.
- Check Power Supply and Ground
- Verify the voltage supply and ground continuity at the EGR connector.
- Repair any open or high-resistance connections.
- Inspect the ECU
- If wiring and actuator are normal, check for signs of overheating or damage in the ECU.
- Replace or reprogram the ECU if needed.
- Clear Fault Codes
- After completing repairs, clear the error memory using Deutz SerDia or equivalent diagnostic software.
- Start the engine and confirm the fault no longer appears.
Additional Information
- System Reaction: Warning indicator, shutoff of actuator output, and possible power reduction.
- Error Lamp Behavior: Permanently ON.
- Self-Healing: Not automatic; manual repair and code clearing required.
- Signal Priority: Level 3 (medium severity).
- Condition at Error Detection: Output shut off by ECU.