How to Solve Deutz EMR3 Engine Power Out Error (74/923)

This guide explains how to diagnose and fix the Deutz EMR3 Engine Power Out error with error codes 74 / 923.

Error Overview

ECU Type: Deutz EMR3 Engine Control Unit (ArHt1)

Error Description: ENGINE POWER OUT

The engine control unit detects that the PWM output current for engine power is outside the normal range, or that the ECU component controlling the output has exceeded its maximum temperature.

Related Software and Tools

Error Code Details

Parameter Description
DEUTZ Error Code 74
Blink Code (short-long-short) 5 – 5 – 5
SPN 923
Possible FMI
FMI 3 Voltage too high or short circuit to +Ubatt
FMI 4 Voltage too low or short circuit to -Ubatt
FMI 5 Current too low or broken wire
FMI 2 Data stream is defective

Error Detection

  • Error Lamp: Constant illumination
  • Error Memory: Fault entry recorded in ECU

Possible Causes

  • Broken or short-circuited engine power output cable
  • Defective output circuit in ECU
  • Damaged or loose connection in wiring harness

Recommended Repair Actions

  1. Inspect wiring: Check for damaged, corroded, or loose cables and connectors.
  2. Test sensor: Verify the condition and signal output of the related sensor.
  3. Replace defective sensor if abnormal readings are detected.
  4. Repair or replace any faulty connection cables.

Additional Error Information

Property Description
System Reaction Warning; output shutoff
Error Lamp Permanently on
Self-Healing No
Signal Priority 1 (High)
Measurement at Error Time Output shutoff value

By following these diagnostic and repair steps, you can effectively resolve the Deutz EMR3 Engine Power Out (74/923) error and restore proper ECU operation.

Be the first to comment

Leave a Reply