Fault Description: Throttle 1
This error relates to the analog accelerator pedal sensor (1) or a dual accelerator pedal sensor. The voltage measured by the ECU is outside the acceptable range, or the calculated pedal position conflicts with the position of the second pedal sensor.
Preparations:
Deutz Diagnostic Kit DECOM for Deutz Engine
2023 Deutz Serdia2010 v14.1.9.1 Diagnostic Software Free Download
Error Code Details
- DEUTZ Error Code: 12
- Blink Code: 2 – 2 – 6 (short-long-short)
- SPN: 91
FMI (Failure Mode Indicator):
- FMI 3: Voltage too high or short circuit to +Ubatt
- FMI 4: Voltage too low or short circuit to -Ubatt
- FMI 12: Error mode cannot be recognized
- FMI 2: Data stream is defective
Error Detection
- The error lamp remains continuously lit.
- Entry is logged in the error memory.
Possible Causes
- Voltage outside the expected range.
- Inconsistent signal compared to the redundant pedal sensor.
- Sensor failure.
- Damaged connecting cables.
Corrective Measures
- Inspect the Wiring:
- Look for damage, corrosion, or loose connections.
- Repair or replace any compromised sections.
- Check the Accelerator Pedal Sensor:
- Test the voltage range to ensure it falls within specifications.
- Verify the signal consistency between redundant sensors (if applicable).
- Replace Faulty Components:
- Replace the sensor if it is found defective.
- Replace or repair the connecting cables if needed.
System Reaction
- The system triggers a warning.
- It may switch to an alternative value based on the priority chain or enter a “limp home” mode.
Error Lamp Behavior
- Continuously lit.
Self-Healing
- No: The error must be manually corrected.
Signal Priority
- Priority Level: 4